114 research outputs found

    Silicon Photomultipliers (SiPM) as novel photodetectors for PET

    Get PDF
    Next generation PET scanners should fulfill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultipliers (SiPMs) is proposed for the construction of a 4D-PET module of 4.8×4.8 cm2 aimed to replace the standard PMT based PET block detector. The module will be based on a LYSO continuous crystal read on two faces by Silicon Photomultipliers. A high granularity detection surface made by SiPM matrices of 1.5 mm pitch will be used for the x–y photon hit position determination with submillimetric accuracy, while a low granularity surface constituted by 16 mm2 SiPM pixels will provide the fast timing information (t) that will be used to implement the Time of Flight technique (TOF). The spatial information collected by the two detector layers will be combined in order to measure the Depth of Interaction (DOI) of each event (z). The use of large area multi-pixel Silicon Photomultiplier (SiPM) detectors requires the development of a multichannel Data Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities and to manage many channels. The paper describes the progress made on the development of the proof of principle module under construction at the University of Pisa

    Data for the modelling of the future power system with a high share of variable renewable energy

    Get PDF
    Energy and power system models have become necessary tools that provide challenges and technical and economic solutions for integrating high shares of Variable Renewable Energy. Models are focused on analysing strategies of power systems to achieve their decarbonisation targets. The data presented in this paper includes the model algorithm, inputs, equations, modelling assumptions, supplementary materials, and results of the simulations supporting the research article titled “Facing the high share of variable renewable energy in the power system: flexibility and stability requirements”. The analysis is based on data from the system operator of one of the European Union member states (Spain). The developed model allows making projections and calculations to obtain the power generation of each technology, the international interconnections, inertia, emissions, system costs and flexibility requirements of new technologies. These data can be used for energy policy development or decision making on power capacity and the balancing needs of the future power system.Ministerio de Ciencia e Innovación PID2020-114725RA-I00Universidad de Sevilla VI PPIT-USPlan nacional I+D+I CTM2016-78089-RJunta de Andalucía P18-RT-451

    Hybrid Monte Carlo dose algorithm for low energy X-rays intraoperative radiation therapy

    Full text link
    Low energy X-rays Intra-Operative Radiation Therapy (XIORT) treatment delivered during surgery (ex: INTRABEAM, Carl Zeiss, and Axxent, Xoft) can benefit from accurate and fast dose prediction in a patient 3D volume

    Efficient methodologies for system matrix modelling in iterative image reconstruction for rotating high-resolution PET

    Get PDF
    A fully 3D iterative image reconstruction algorithm has been developed for high-resolution PET cameras composed of pixelated scintillator crystal arrays and rotating planar detectors, based on the ordered subsets approach. The associated system matrix is precalculated with Monte Carlo methods that incorporate physical effects not included in analytical models, such as positron range effects and interaction of the incident gammas with the scintillator material. Custom Monte Carlo methodologies have been developed and optimized for modelling of system matrices for fast iterative image reconstruction adapted to specific scanner geometries, without redundant calculations. According to the methodology proposed here, only one-eighth of the voxels within two central transaxial slices need to be modelled in detail. The rest of the system matrix elements can be obtained with the aid of axial symmetries and redundancies, as well as in-plane symmetries within transaxial slices. Sparse matrix techniques for the non-zero system matrix elements are employed, allowing for fast execution of the image reconstruction process. This 3D image reconstruction scheme has been compared in terms of image quality to a 2D fast implementation of the OSEM algorithm combined with Fourier rebinning approaches. This work confirms the superiority of fully 3D OSEM in terms of spatial resolution, contrast recovery and noise reduction as compared to conventional 2D approaches based on rebinning schemes. At the same time it demonstrates that fully 3D methodologies can be efficiently applied to the image reconstruction problem for high-resolution rotational PET cameras by applying accurate pre-calculated system models and taking advantage of the system's symmetries

    Recent Trends in SST, Chl-a, Productivity and Wind Stress in Upwelling and Open Ocean Areas in the Upper Eastern North Atlantic Subtropical Gyre

    Get PDF
    The global upper ocean has been warming during the last decades accompanied with a chlorophyll-a (Chl-a) and productivity decrease. Whereas subtropical gyres show similar trends, Eastern Boundary Upwelling Systems are thought to increase in productivity due to increased trade winds. This study analyzes recent trends in sea surface temperature (SST), Chl-a, net primary production (NPP) and meridional wind stress in the Eastern North Atlantic subtropical gyre (NASE) in order to examine if the global trends can be detected in open ocean and upwelling areas and how the ocean biota responds. Satellite data of such variables of the last 15–40 years were analyzed to calculate mean trends in upwelling areas in the Canary upwelling system and open ocean areas around the Azores, Madeira and the Canary Islands. Our results show significant warming in the area with a maximum of 2.7°C per century for the Azores. Moreover, a general decreasing trend for Chl-a and NPP seems to be more evident in the permanent upwelling areas, which will be responsible for a loss of 0.13% of the global NPP per century. Our results also highlight a significant expansion of the oceanic desert area of 10% with an increase in unproductive days of up to 84 days in the last 20 years. The competitive relationship of stratification and wind stress in the Canary upwelling system might be a more plausible explanation for the decrease in Chl-a and NPP in upwelling areas linked to the increase in upwelling favorable wind stress and the surface warming.En prens

    Projector Model for Efficient List-Mode Reconstruction in PET Scanners with Parallel Planar Detectors

    Get PDF
    We have developed a new projector model specifically tailored for fast list-mode tomographic reconstructions in Positron emission tomography (PET) scanners with parallel planar detectors. The model provides an accurate estimation of the probability distribution of coincidence events defined by pairs of scintillating crystals. This distribution is parameterized with 2D elliptical Gaussian functions defined in planes perpendicular to the main axis of the tube of response (TOR). The parameters of these Gaussian functions have been obtained by fitting Monte Carlo simulations that include positron range, acolinearity of gamma rays, as well as detector attenuation and scatter effects. The proposed model has been applied efficiently to list-mode reconstruction algorithms. Evaluation with Monte Carlo simulations over a rotating high resolution PET scanner indicates that this model allows to obtain better recovery to noise ratio in OSEM (ordered-subsets, expectation-maximization) reconstruction, if compared to list-mode reconstruction with symmetric circular Gaussian TOR model, and histogram-based OSEM with precalculated system matrix using Monte Carlo simulated models and symmetries

    Proof of concept of an imaging system demonstrator for PET applications with SiPM

    Get PDF
    A PET imaging system demonstrator based on LYSO crystal arrays coupled to SiPM matrices is under construction at the University and INFN of Pisa. Two SiPM matrices, composed of 8×8 SiPM pixels, and 1,5 mm pitch, have been coupled one to one to a LYSO crystals array and read out by a custom electronics system. front-end ASICs were used to read 8 channels of each matrix. Data from each front-end were multiplexed and sent to a DAQ board for the digital conversion; a motherboard collects the data and communicates with a host computer through a USB port for the storage and off-line data processing. In this paper we show the first preliminary tomographic image of a point-like radioactive source acquired with part of the two detection heads in time coincidence

    Characterization and Test of a Data Acquisition System for PET

    Get PDF
    A small Positron Emission Tomography demonstrator based on LYSO slabs and Silicon Photomultiplier matrices is under construction at the University and INFN of Pisa. In this paper we present the characterization results of the read-out electronics and of the detection system. Two SiPM matrices, composed by 8 × 8 SiPM pixels, 1.5 mm pitch, have been coupled one to one to a LYSO crystals array. Custom Front-End ASICs were used to read the 64 channels of each matrix. Data from each Front-End were multiplexed and sent to a DAQ board for the digital conversion; a motherboard collects the data and communicates with a host computer through a USB port. Specific tests were carried out on the system in order to assess its performance. Futhermore we have measured some of the most important parameters of the system for PET application

    Validation of a phase space determination algorithm for intraoperative radiation therapy

    Full text link
    Monte-Carlo (MC) methods are a valuable tool for dosimetry in radiotherapy, including Intra-Operative Electron Radiotherapy (IOERT), since effects such as inhomogeneities or beam hardening may be realistically reproduced

    Asymmetric data acquisition system for an endoscopic PET-US detector

    Get PDF
    According to current prognosis studies of pancreatic cancer, survival rate nowadays is still as low as 6% mainly due to late detections. Taking into account the location of the disease within the body and making use of the level of miniaturization in radiation detectors that can be achieved at the present time, EndoTOFPET-US collaboration aims at the development of a multimodal imaging technique for endoscopic pancreas exams that combines the benefits of high resolution metabolic information from time-of- flight (TOF) positron emission tomography (PET) with anatomical information from ultrasound (US). A system with such capabilities calls for an application-specific high-performance data acquisition system (DAQ) able to control and readout data from different detectors. The system is composed of two novel detectors: a PET head extension for a commercial US endoscope placed internally close to the region-of-interest (ROI) and a PET plate placed over the patient's abdomen in coincidence with the PET head. These two detectors will send asymmetric data streams that need to be handled by the DAQ system. The approach chosen to cope with these needs goes through the implementation of a DAQ capable of performing multi-level triggering and which is distributed across two different on-detector electronics and the off-detector electronics placed inside the reconstruction workstation. This manuscript provides an overview on the design of this innovative DAQ system and, based on results obtained by means of final prototypes of the two detectors and DAQ, we conclude that a distributed multi-level triggering DAQ system is suitable for endoscopic PET detectors and it shows potential for its application in different scenarios with asymmetric sources of data
    corecore